TOB-CT-4008-5V30A-NFA Battery and Super Capacitor Tester is mainly used for lithium battery and supercapacitor performance testing with charging and discharging life cycle testing system.

•Item number:TOB-CT-4008-5V30A-NFA

•Certificate:CE,ISO

•Lead time:40days

•MOQ:1set

•Origin:China

8 Channels 5V30A Lithium Battery and Supercapacitor Tester

tob technology

TOB-CT-4008-5V30A-NFA Battery and Supercapacitor Tester is mainly used for lithium battery

and supercapacitor performance testing with charging and discharging life cycle testing system.

Project index Parameter index
Input Power AC 220V ±10% / 50Hz (AC110V/60HZ)
resolution AD:16bit;DA:16bit
Input Resistance ≥1MΩ
Input Power 2127W
Channel Features Constant Current Source and Constant Voltage Source

with Independent pairs of Closed-loop Structure

Channel Control Mode Independent Control
Voltage Per Channel Voltage Range Charge: 25mV~5V;Discharge:25mV~5V
Discharge Min Voltage 2.5V
Accuracy ± 0.05% of FS
Stability ± 0.05% of FS
Current Per Channel Current Range Charge:150mA~30A;Discharge:150mA~30A
Accuracy ± 0.05% of FS
Stability ± 0.05% of FS
Power Per Channel Output Power 150W
Stability ± 0.1% of FS
Time Current Response Time 1ms (0-Full Range)
Step Time Range ≤(365*24 )hour/step,

Time Form Support 00:00:00(h、min:s、ms)

Data Recording Record Condition Lower sampling time:100ms
Lower sampling Voltage:5mV
Lower sampling Current:30mA
Record Frequency 10Hz
Charge Charge Mode Constant Current Charge、Constant Voltage Charge、

Constant Current and Constant Voltage Charge、CPC

End Conditon Voltage、Current、Relative Time、Capacity
Discharge Discharge Mode CCD、CPD、CRD
End Condition Voltage、Current、Relative Time、Capacity、
Pulse charge CCC
Discharge CCD
Min Pulse Width 500ms
Automated Switch Automated swith from charge to discharge for each pulse
End Condition Voltage, Test Time
Cycle Loop Measure Range 1~65535 times
Max Steps Per Loop 254
Nested Loop Nested loop Function,Max Support 3 Layers
Protection Software Protection l Power-down Data Protection
l Off-line Testing Function
l Setting Protection Condition,Setting Parameter:

Low Voltage limit、Upper Voltage limit、Low Current limit、

Upper Current limit、Delay Time

Hardware Protection Additional Anti-reverse Protection Model
Voltage and Current Testing Sample 4-wire connecting
Noise <85dB
Database MySQL Database
A Means of Communication of Upper Machine TCP/IP Protocol
Data Output EXCEL、TXT、Graph
Communication Interface Ethernet Port
Per Unit Main Channels No. 8
Dimensions 12U,482*508*378(mm)

 